Chapter 6: Maintenance and troubleshooting
98-141368-A 102
08010 Undervoltage has
been detected
The input voltage has dropped
below an acceptable level. The
terminal will be shut down in
10 seconds if the situation
persists.
Ensure a stable power supply to
the terminal.
0801B Lost connection
to the GPS
receiver
Communication with the GPS
receiver in the antenna is lost.
Restart the terminal.
Contact your distributor if the
warning persists.
0801D Uploading
firmware to
antenna
New firmware is being
uploaded to the antenna.
The Event will be cleared when
upload has finished.
Contact your distributor if the
Event is not cleared within 5
minutes.
0802C Firmware update
still fails
after several
retries
The terminal was unable to
upload new firmware to the
antenna.
Contact your distributor.
0802D Firmware update
failed
The terminal was unable to
upload new firmware to the
antenna.
Reboot the terminal. Then
update the software again.
Contact your distributor if the
problem persists.
0802E Firmware is
older than
current antenna
version
The firmware in the antenna is
newer than expected by the
terminal.
Update the terminal software.
0802F Antenna main
image could not
be loaded
Antenna failed to start up
normally.
Reboot the terminal.
Contact your distributor if the
problem persists.
08030 Antenna could
not enter main
application mode
Antenna failed to start up
normally.
Reboot the terminal.
Contact your distributor if the
problem persists.
08031 Failed to enter
normal operation
Antenna failed to start up
normally.
Reboot the terminal.
Contact your distributor if the
problem persists.
08032 Firmware image
version lower
than active
antenna version
The firmware in the antenna is
newer than expected by the
terminal.
Update the terminal software.
ID Event Text Explanation Remedy
Comentarios a estos manuales